Cleanroom & GMP Antistatic Epoxy Floor System

SKU: FW-SLF-CRN

A seamless, non-shedding ESD floor supplied as a system: earthed copper grid, conductive layers, 2–3 mm antistatic self-levelling body and a coved upstand, with resistance verified on the finished floor.

Key Parameters

Finish
Low-sheen / satin
Thickness
3 mm
Coverage
2.2 kg/m²/mm
Mix Ratio
A:B = 4:1
Walk-on Time
10 h

Standard pack: 20 kg/set (A: 15 kg + B: 5 kg). Reply within 24 hours. Custom RAL colours and OEM packaging available.

  • ISO 9001
  • SGS
  • CE
  • French A+
  • PICC

System line:Self-Leveling Epoxy > Anti-Static Self-Leveling

Why buyers specify it

A seamless, non-shedding ESD floor supplied as a system — earthed copper grid, conductive layers, 2–3 mm antistatic self-levelling body and a coved upstand — with resistance verified on the finished floor, not on the paint tin.

Product overview

A cleanroom floor supplied as a build-up rather than as a coating: 3 mm poured at 2.2 kg/m² per mm, low-sheen, mixed A:B = 4:1 from a 20 kg set (15 kg resin + 5 kg hardener). It holds >80 Shore D and 78 MPa compressive with 3 MPa adhesion, wears at ≤0.03 g on the Taber plate, and carries a French A+ indoor-emission classification. 30 minutes of pot life at 20 °C, walk-on at about 10 hours, full cure at 7 days.

Three questions a cleanroom floor is asked

A cleanroom floor is judged on three things and none of them is colour: it must not shed particulate of its own, it must wipe down to a dry surface, and where electronics or flammable powders are handled it must move static charge away in a controlled way. A paint-only answer fails the third, because an antistatic topcoat with nothing underneath and nowhere to discharge to is decoration, not static control — so we supply the grid, the conductive layers, the body and the earth point as one system.

The base build here is the same system as our anti-static self-leveling epoxy; what this page adds is the cleanroom detailing — the coved upstand at the wall line, the sequencing around other trades, and the record that goes with it.

What the handover pack has to contain

In a qualified facility the floor is not signed off on appearance, so the paperwork is part of the delivery. The number that matters is measured on the completed floor, per area, under the conditions the room was actually in when it was poured — not on the paint tin and not on a test panel made in the factory. What we hand over is the build as laid, the area it covers, the ambient conditions at application, and the readings taken on the finished surface. What we do not hand over is a room classification: a floor does not make a cleanroom, the envelope, the filtration, the air changes and the pressure cascade do. Anyone offering to certify the room with the flooring is selling something other than a floor.

Sequencing is the part that goes wrong

  • Gowning traffic waits for the wear coat to set; light return is a three-day conversation on this build, and full service at 7 days.
  • Wet cleaning and equipment wheels come after full cure, not after the room looks finished — a trolley moved in on day three leaves a mark that stays for the life of the floor.
  • The plant runs during application, not after it, because a cold slab under a warm room crosses the dew point and blushes the film.
  • Other trades that make dust work before the floor, not after it.

Where it is the wrong pick

This is not a floor for a hot-wash bay, a steam-cleaned area or a cold room — those need a binder chemistry we do not manufacture, and we will say so rather than sell you a floor with an expiry date. A production area that needs static control for electronics but has no classification paperwork is better served by the base anti-static build. Send the room list, the cleaning agents with their dilutions, and the resistance your spec writer has called for: the target comes from your qualification document, not from our data sheet.

A cleanroom floor is judged on three things and none of them is colour. It must not shed particulate of its own, it must be possible to wipe right down to a dry surface, and — where electronics or flammable powders are handled — it must move static charge away from people and equipment in a controlled way. A paint-only answer fails the third one, because an antistatic topcoat with nothing underneath and nowhere to discharge to is decoration, not static control.

So we specify this as a build-up: substrate thresholds confirmed first, then a copper tape grid tied to a documented earth point, a conductive primer and intermediate layer over it, the antistatic self-levelling body at 2–3 mm, and a coved upstand of the same material at the wall base. Resistance is then measured on the completed floor and recorded, because that is the only number that means anything to your validation file.

What we do not claim. A floor does not make a room ISO Class — classification is a property of the whole room (envelope, filtration, air changes, pressure cascade and behaviour) and is verified on site. And the wet, hot-washed rooms in a food plant — cook-line floors, CIP areas, wash bays — need a polyurethane cement mortar system; we do not manufacture it, and we will say so rather than let you discover it after handover.

System build-up (typical, per m²)

SubstrateThresholds confirmed firstCompressive ≥ 25 MPa, moisture < 4 %, pH < 9, 2 m straightedge gap ≤ 2 mm
PrepGrind + vacuumRemove laitance, old sealers and any adhesive residue; dust extraction throughout
EarthCopper tape grid + earth pointGrid laid and tied to a documented earth; continuity checked and recorded before anything covers it
Conductive layerPrimer + intermediateConductive epoxy primer worked into the grid, then the conductive intermediate coat
Body2–3 mm antistatic self-levelling≈ 2.2 kg/m² per mm, squeegee-poured and spiked; coved upstand formed at the wall base
FinishESD wear coatLow-sheen, cleanable; then resistance is measured, recorded and handed over

Rated features

  • antistatic
  • seamless
  • coved-detail
  • low-VOC
  • dust-proof
  • chemical-resistant

Colour options

  • Light Grey
  • Mid Grey
  • Blue Grey
  • Custom RAL

Custom RAL matching available — we ship a physical sample card before production.

Made in Our Own Factory

Dongguan Friway Hydraulic Control Technology Co., Ltd.

Every batch of Cleanroom & GMP Antistatic Epoxy Floor System is produced in our own facility by a team that integrates R&D, production, sales and technical service. Advanced equipment, batch-level lab testing and a complete quality system mean consistent quality — from the first sample to the last pallet.

French A+ indoor air emission rating
French A+ Indoor Air — lowest emissions class
PICC product liability insurance
Product liability insured by PICC

Questions about production, certificates or MOQ?

Ask Our Team
  • ISO 9001Quality management system for the flooring coatings lineCertificate copy + audit scope on request
  • SGS testedAdhesion, hardness, abrasion and VOC on finished filmTest report per batch on request
  • CE / DoCDeclaration of conformity for European projectsDoC issued with shipment documents
  • French A+ VOCIndoor air-emission class for living-space floorsClassification sheet on request
  • PICC product liabilityProduct liability cover for exported goodsPolicy summary on request
  • MSDS / SDSPer component — needed for sea and air freight approvalIssued with every shipment

Certificates & Lab Reports

This product line is verified by third-party laboratories. The marks shown above are the ones we publish as images; the documents behind them — certificate copies, batch-specific test reports, the CE Declaration of Conformity — are issued on request. A scanned badge proves nothing about your slab; the report behind it does.

Request PDF Copies

Get a Free Quote

Need a Specification for Your Slab?

Send the floor area, substrate condition and what the room has to take. We reply with the system build-up, coverage estimate and an FOB quotation — usually within 24 hours.

  1. Tell us about the floorArea in m², substrate condition, and the finish or colour you want.
  2. Get a technician's replyWithin 24 hours: system build-up, coverage estimate, pricing and TDS/MSDS.
  3. Confirm colour & sampleFree colour chips and a cured sample panel before you place an order.

* Required fields. Your information is only used to respond to your inquiry.

Request a Quote

We reply within 24 hours

* Required fields. Your information is only used to respond to your inquiry.